Network / Data Center
DLLSTX2: Stemmons Freeway, Dallas, TX
78,500 sq. ft. facility
35,500 sq. ft. raised floor
(23) HVAC units totaling 574 tons
Very Early Smoke Detection Apparatus (VESDA)
Pre-action dry pipe sprinkler system
Over 500 smoke detectors in integrated system
Northern Proximity security badge entry/exit
Multiple TXU electrical grids
4800 amps of 480v input power
3 main transfer switches
(3) 500KVA Power-ware UPS units, 90 batteries each
Standalone PDUs at each cabinet row
1-megawatt generator (2000 gallon tank)
1.5-megawatt generator (2200 gallon tank)
DataTrax monitoring for all datacenter infrastructure
DLLSTX4: Downtown, Dallas, TX
22,000 sq. ft. facility
18,000 sq. ft. raised floor
(12) 26-ton Data Air AC units
Very Early Smoke Detection Apparatus (VESDA)
Pre-action dry pipe sprinkler system
Over 220 smoke detectors in integrated system
Northern Proximity security badge entry/exit
TXU fault tolerant electrical grid
2000 amps of 480v input power
1 main transfer switches
(2) 500KVA Powerware UPS units, 90 batteries each
Standalone PDUs at each cabinet row
1.5-megawatt generator (2200 gallon tank)
DLLSTX5: Infomart, Dallas, TX
51,000 sq. ft. facility
35,000 sq. ft. raised floor
(25) HVAC units totalling 775 tons
Very Early Smoke Detection Apparatus (VESDA)
Pre-action dry pipe sprinkler system
Over 400 smoke detectors in integrated system
Northern Proximity security badge entry/exit
Multiple TXU fault tolerant electrical grid
4600 amps of 480v input power
3 main transfer switches
(6) 500KVA Powerware UPS units, 120 batteries each
Standalone PDUs at each cabinet row
3.5-megawatts of generating capacity
DLLSTX6: Stemmons Freeway, Dallas, TX
72,000 sq. ft. facility
(8) HVAC units totalling 240 tons (expanding to 1650 tons)
Dual 550 ton carrier chillers (adding one more)
Very Early Smoke Detection Apparatus (VESDA)
Pre-action dry pipe sprinkler system
Over 500 smoke detectors in integrated system (increasing to 1000)
Northern Proximity security badge entry/exit
Network Infrastructure:
Choosing Host Gator means that your sites will be accessible via a fully meshed and redundant Certified Cisco Network featuring 10 backbone providers. These providers include: