Web Hosting - Infrastructure

Tired of bouncing from host to host?

99.9% uptime, 30 day money back guarantee. Your site will be on a top-of-the-line Dual Xeon server that can provide instant backups of your site (this is available via the control panel). Our control panel is one of the best in the industry, and has over 52 scripts that can be installed with a click of the mouse.

Network / Data Center

DLLSTX2: Stemmons Freeway, Dallas, TX

  • 78,500 sq. ft. facility
  • 35,500 sq. ft. raised floor
  • (23) HVAC units totaling 574 tons
  • Very Early Smoke Detection Apparatus (VESDA)
  • Pre-action dry pipe sprinkler system
  • Over 500 smoke detectors in integrated system
  • Northern Proximity security badge entry/exit
  • Multiple TXU electrical grids
  • 4800 amps of 480v input power
  • 3 main transfer switches
  • (3) 500KVA Power-ware UPS units, 90 batteries each
  • Standalone PDUs at each cabinet row
  • 1-megawatt generator (2000 gallon tank)
  • 1.5-megawatt generator (2200 gallon tank)
  • DataTrax monitoring for all datacenter infrastructure

DLLSTX4: Downtown, Dallas, TX

  • 22,000 sq. ft. facility
  • 18,000 sq. ft. raised floor
  • (12) 26-ton Data Air AC units
  • Very Early Smoke Detection Apparatus (VESDA)
  • Pre-action dry pipe sprinkler system
  • Over 220 smoke detectors in integrated system
  • Northern Proximity security badge entry/exit
  • TXU fault tolerant electrical grid
  • 2000 amps of 480v input power
  • 1 main transfer switches
  • (2) 500KVA Powerware UPS units, 90 batteries each
  • Standalone PDUs at each cabinet row
  • 1.5-megawatt generator (2200 gallon tank)

DLLSTX5: Infomart, Dallas, TX

  • 51,000 sq. ft. facility
  • 35,000 sq. ft. raised floor
  • (25) HVAC units totalling 775 tons
  • Very Early Smoke Detection Apparatus (VESDA)
  • Pre-action dry pipe sprinkler system
  • Over 400 smoke detectors in integrated system
  • Northern Proximity security badge entry/exit
  • Multiple TXU fault tolerant electrical grid
  • 4600 amps of 480v input power
  • 3 main transfer switches
  • (6) 500KVA Powerware UPS units, 120 batteries each
  • Standalone PDUs at each cabinet row
  • 3.5-megawatts of generating capacity

DLLSTX6: Stemmons Freeway, Dallas, TX

  • 72,000 sq. ft. facility
  • (8) HVAC units totalling 240 tons (expanding to 1650 tons)
  • Dual 550 ton carrier chillers (adding one more)
  • Very Early Smoke Detection Apparatus (VESDA)
  • Pre-action dry pipe sprinkler system
  • Over 500 smoke detectors in integrated system (increasing to 1000)
  • Northern Proximity security badge entry/exit

 

Network Infrastructure:

Choosing Host Gator means that your sites will be accessible via a fully meshed and redundant Certified Cisco Network featuring 10 backbone providers. These providers include:

Backbone Carriers

  • 3 Gbps Direct Fiber - Global Crossing
  • 3 Gbps Direct Fiber - UUNET
  • 5 Gbps Direct Fiber - AT&T
  • 4 Gbps Direct Fiber - Level3
  • 4 Gbps Direct Fiber - AboveNet
  • 4 Gbps Direct Fiber - Savvis
  • 1 Gbps Direct Fiber - Time Warner
  • 4 Gbps Direct Fiber - Private Peers

Network

  • Cisco Certified Network
  • Juniper M20 Border Routers
  • Cisco 6500 Series Distribution Routing Switches
  • Cisco 6500 Series Aggregation Switches
  • 100% Uptime SLA utilizing HSRP/BGP

Building Fiber

  • OC48 SONET Ring - SBC
  • OC48 SONET Ring - Time Warner
  • OC48 SONET Ring - XO Communications
  • OC48 SONET Ring - MCI
  • OC48 SONET Ring - Looking Glass
  • OC48 SONET Ring - Broadwing